Features | |
Max size: (W x H) | 8000 × 6000 mm (larger sizes available on request) |
Panel thickness: | 42mm |
Panel material: | Microrilled steel |
Filling: | CFC-free polyurethane (water blown). Reaction to fire classification according to EN13501: C‑s3, d0. |
Weight: | Steel: 13 kg/m2 |
Color outside: | 13 standard RAL colors |
Color inside: | RAL 9002 |
Track types: | Standard: SL Optional: HL, LL, VL, HHL, SLL |
Windows: | Optional: DARP, TARP, DAOP, Framed section |
Passdoor: | Optional: In door leaf with low threshold and standard threshold |
Electrical operation: | Optional: Automated operation, Access control, Safety functions |
Performance | |
Opening/closing speed: | IDO7: 0.25 m/s IDO7 HD: 0.18 m/s IDO7 2H: opening 0.5 m/s, closing 0.25 m/s |
Life time expectations: | Door: 200000 door cycles or 10 years, when service/replacement program has been performed Springs: 20000 door cycles |
Resistance to wind load, EN 12424 (Insulated panel sections) | Class 3 (DLW ≤ 4250) Class 2 (4250 < DLW) (Higher classes on request) |
Resistance to wind load, EN 12424 (Framed panel sections) | Class 3 (DLW ≤ 3650) Class 2 (3650 < DLW) (Higher classes on request) |
Thermal transmittance, EN12428 | 1,0 W/(m2∙K) Steel door, full panel (Door surface 5000 x 5000 mm, no passdoor) Thermal calculations on exact door sizes and configurations are available on request |
Resistance to Water penetration, EN12425 | Class 3 (no passdoor) |
Air permeability, EN12426 | Class 3 (no passdoor) |
Acoustic insulation, EN ISO 10140-2 | R - 25 dB (no passdoor) |
Weather resistant
Thanks to the solid construction, the Dynaco I-14P Panel sectional overhead door is wind resistant up to class 3 of the European standard EN12424. Insulated panels designed without thermal bridge reduce thermal transmittance and consequent energy costs.
Reliable and safe
This exterior sectional overhead door protects your premises against intrusion. Extra safety devices can block downward door movement to assure user safety.